Home ProductsSplit Case Water Pump

39m Head 485m3/h Double Suction Split Case Single Stage Water Pump 250S39

Certification
China CHANGSHA SANCHANG PUMP CO., LTD. certification
China CHANGSHA SANCHANG PUMP CO., LTD. certification
I'm Online Chat Now

39m Head 485m3/h Double Suction Split Case Single Stage Water Pump 250S39

large.img.alt
large.img.alt

Large Image :  39m Head 485m3/h Double Suction Split Case Single Stage Water Pump 250S39

Product Details:
Place of Origin: CHINA
Brand Name: SANCHANG
Certification: ISO9001
Model Number: 250S39
Payment & Shipping Terms:
Minimum Order Quantity: 1 pcs
Price: Negotiated
Packaging Details: Plywood Case
Delivery Time: 30 working days
Payment Terms: L/C, T/T
Supply Ability: 300pcs/month
Detailed Product Description
Flow Capacity: 485m3/h Delivery Head: 39m
Inlet/Outlet Dia.: 250/200mm Working Pressre: 0.4MPa
Liquid Temperature: 0-80 ℃ Application: Clean Water, Sewage, Hot Water, Corrosive Liquid, Mining Water
Material: Cast Iron, Cast Steel, S.S304, S.S316, Duplex S.S2205 Driven By: Electric Motor / Diesel Engine
Voltage: 380V/415V/440V/460V/660V/3.3kV/6kV/10kV Speed: 1480/1760rpm
Seal: Gland Packing/Mechanical Seal Frequency: 50 /60 Hz
High Light:

39m Head Single Stage Water Pump

,

Single Stage Water Pump 250S39

,

485m3/h Double Suction Split Case Pump

39m head, 485m3/h flow capacity, Single Stage Double Suction Split Case Water Pump 250S39

 

 

A horizontal split case pump is a unique type of centrifugal pump whose casing is divided into two distinct chambers, which is different from inline or end suction pumps that are assembled with the suction nozzle, discharge nozzle, and casing in one chamber.

 

Horizontal split-case (HSC) pumps are used in most industries around the world to move large quantities of fairly clean fluids—usually water—at low to medium pressures. HSC design geometry poses numerous advantages and disadvantages for users.

 

Parameters of 250S39

Flow Capacity 300-600 m3/h Delivery Head 20-40 m
Inlet/Outlet Dia. 250/200 mm Working Pressure ≤ 0.4 MPa
Liquid Temperature 0 - 80 ℃ Driven By Electric Motor / Diesel Engine
Seal Type Mechanical seal / Gland packing Liquid Clean water or similar
Material of Construction Cast Iron / Cast Steel / S.S304 / S.S316 / Duplex S.s2205

 

Model Flow Rate

Head

(m)

Speed

rpm

Power N(kW)

Eff.

(%)

NPSHr

(m)

Inlet/Outlet

Dia. (mm)

Weight (kg)
m3/h L/S Shaft Motor
250S39

360

485

612

100

134.7

170

42.5

39

32.5

1450

54.8

62.1

68.6

75

76

83

79

3.2 250/200 620
250S39A

324

468

576

90

130

160

35.5

30.5

25

1450

42.3

49.2

50.9

55

74

79

77

3.2 250/220 620

 

Main Parts Configuration

To meet the demands of multiple applications, which requires that pumps or parts are constructed in a specified material, the Sanchang split case pumps are available in a wide range of materials:
• Cast iron
• Ductile cast iron
• Bronze
• Nickel aluminum bronze
• Stainless steel
• (Super) duplex stainless steel
• Other materials on request

 

Here followed our recommendation of main configuration:

Parts Name Clean Water Sewage Hot Water Corrosive Liquid Oil Liquid
Pump Body Cast Iron Ductile Iron Cast Steel/S.S304 S.S304/S.S316/S.S2205 S.S304/S.S316
Shaft Cast Iron S.S420 S.S420/42CrMo S.S630 S.S420/40Cr
Shaft Sleeve Carbon Steel S.S420 S.S304 S.S316/S.S630/S.S2205 S.S304/S.S316
Impeller Cast Iron Ductile Iron Cast Steel/S.S304 S.S304/S.S316/S.S2205 S.S304/S.S316
Wearing Ring Cast Iron Ductile Iron Cast Steel/S.S304 S.S304/S.S316/S.S2205 S.S304/S.S316
Bearing China Make/NSK/SKF/Customized
Seals Mechanical Seals/Gland Packing Seals

 

Split case pumps have been specifically engineered to meet the needs and requirements of the oil, gas and process industries. Tough and robust products are required which have proven long term reliability and benefits, enabling them to perform in often arduous operational and environmental conditions - where dependability is of paramount importance.

 

Advantages of HSC pumps:

HSC pumps have a smaller footprint compared with a frame-mounted pump of the same rating (in most cases).
The top half of the casing is easy to remove for inspection of the rotor, and you do not need to disturb the driver or the piping to accomplish this inspection.
They typically have higher efficiencies than frame-mounted pumps of the same size.
Because of the dual-eye (dual-suction) impeller design, there are lower net positive suction head required (NPSHR) factors and lower axial thrust.
This design lends itself to a short shaft with the result of low deflection. This article limits the discussion to one- or two-stage HSC pumps with the impeller situated between the bearings; this design is also known as “between bearings” (API 610- BB-1).
Typically these pumps offer dual volute construction, which significantly reduces the radial thrust component.

 

Applications

General residential & industrial water supply & transferring;
Agricultural irrigation & drainage, Flood discharge & Emergency drainage;
Civil water treatment, Waterworks, Sea water desalination;
Air-conditioning, Fire-fighting facilities, High building water supply;
Oil & Gas & Chemical processing, Abrasive liquids transferring;
Power plant water circulation, Cooling tower & Hot water transferring
Mining, Boiler feeding, etc.

 

39m Head 485m3/h Double Suction Split Case Single Stage Water Pump 250S39 0