Home News

Failure causes and solutions of GDL vertical inline multistage centrifugal pump

Certification
China CHANGSHA SANCHANG PUMP CO., LTD. certification
China CHANGSHA SANCHANG PUMP CO., LTD. certification
I'm Online Chat Now
Company News
Failure causes and solutions of GDL vertical inline multistage centrifugal pump
Latest company news about Failure causes and solutions of GDL vertical inline multistage centrifugal pump

Fault 1: in case of vertical multistage pump, the pointer of non suction pressure gauge and vacuum gauge jumps violently.
Cause of failure: the suction head is too high, the filling water is not enough, the connection between the pipeline and the instrument is abnormal, and there is air outflow.
Solution: check the bottom valve for water leakage, and then hire enough water to tighten the air leakage.

 

Fault 2: vertical multistage pump does not absorb water, the vacuum gauge may indicate high vacuum.
Cause of failure: the filter is blocked, the bottom valve is not opened, in other words, the resistance of the suction pipe is too large.
Solution: check the bottom valve. Replace water absorption. Clean the filter carefully.

 

Fault 3: vertical multistage pump pressure gauge has pressure, but still can not water.
Cause of failure: the impeller is blocked. It may be that the outlet pipe resistance is too large, the rotation direction is incorrect, and the outlet pipe valve is not opened.
Solution: check the short water pipe carefully. Check the motor two-phase mutual adjustment. Start the outlet valve. Remove the dirt in the impeller.